Concrete sand gravel aggregate.
R value of concrete block wall nz.
Options for a 20 series 190 mm all cells filled concrete block wall to meet the schedule method are.
Risks when installing home insulation has information about underfloor insulation.
0 13 0 64 30.
Built by esd consultants low impact development lid consulting in melbourne australia the r value calculator is a practical tool to simplify total insulation calculations.
For example a typical polystyrene block wall construction consists of two layers of 50 mm eps polystyrene r value 1 31 and 150 mm concrete core r value 0 09.
R1 1 1 4 for 45 mm insulation r1 7 2 2 for 90 mm insulation.
R value calculator select product please select thermaslab s thermaslab m thermaslab h platinum board expol x select thickness please select 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250.
If one layer of polystyrene is removed the r value of the wall will be r1 4.
Our insulation calculator enables simple calculation of total wall roof ceiling or floor system insulation r values.
This gives a total r value of r2 71 this does not include any plaster coatings to either face.
Concrete stab on ground r 1 3.
8 thick concrete slab or foundation wall has an r value of about 1 04 30 while lightweight aggregate filled 8 thick concrete has an r value of about 2 18 30.
Insulation options are shown below.
Timber framed wall and weatherboard cladding r 2 0.
It uses the iso thermal planes method the same method as used in nzs4214 2006.
This webpage calculates the r value of walls roofs and suspended floors for most insulation material r values.
Some of the possible material combinations may not be suitable for actual constructions i e.
A 90 mm framed false wall with studs at 600 mm centres and dwangs at 1200 mm centres with insulation of r2 0 or better a 70 mm framed false wall with studs at 600 mm centres and dwangs at.
Installing underfloor foil insulation can be risky.
For instance if you have a material with an r value of 12 attached to another material with an r value of 3 then both materials combined have an r value of 15.
Concrete block makes a cost effective and structurally sound wall but it has little thermal resistance.
As we said before the r value measures the thermal resistance of a material.
Suspended timber froor r 1 3.
Eps based claddings directly fixed on timber framing.
Strapping and lining depending on the particular type of insulation used and the wall thickness will provide an r value of between.
Mum wall r value is r1 9.