Screw the new panel in place as described.
Roof anchor installation instructions.
Always install the anchor device so no part of the device is less 2 5 m from the edge of the roof or opening.
Lay flat cap nail flat.
Both permanent and temporary roof anchor points are available.
Installation of this roof anchor must be certified by a qualified person or engineering service.
Each of our roofing technicians has received extensive training to properly install roof anchors within the rules and regulations of osha.
Do not stretch during installation.
Roof anchors installed for restraint applications must be attached to a roof member capable of sustaining a static load of at least 3 000 lbs.
You may need to cut panels to fit angles using a circular saw with a metal saw blade.
Roof anchors can be as simple as a d ring connection or as complex as a complete lifeline system.
Not for use as an abseiling point.
The users must read and abide by the manufacturer s instructions for each element of the system.
If the material is not able to support 5 000 lbs.
2 way roof anchor installation instructions this product is part of a personal fall arrest system.
Anchor points are usually installed on the roof and are used to connect lanyards lifelines and other forms of tie off which prevent a worker from falling.
The silicone will spread and adhere creating a seal.
In general roof anchors should be installed on roofs or structures that are made of wood and sheathing.
During installation and assembly of the anchor device ensure that the installer is not less that 2 m from any edge or opening.
Reliable roofing is a professional commercial roofing contractor that can provide roof anchor installation services in lake zurich il and the north chicago suburbs.
3 0 operation and use.
Install the panel so that the short lip overlaps the large lip.
Continue adding panels until the roof is covered.
Slopes 4 12 and more a lay out anchordeck synthetic roofing underlayment horizontally parallel to the eave with the printed side up.
Minimum tensile load a qualified person must confirm that the support structure maintains a safety factor of two as per osha 1926 502.
The roof material must be capable of supporting a minimum tensile load of 5 000 lbs.
Metal roofing is also available in the form of shingles.
Installation guidelines for different slopes categories are listed below.
B install anchordeck synthetic roofing underlayment without wrinkles.
Applied in any direction permitted by the restraint system when in use.